Table
Table
Table 3
3
3 Typical
Typical
Typical Installation
Installation
Installation —
—
— Pump
Pump
Pump with
with
with Open
Open
Open Wet
Wet
Wet Cup
Cup
Cup Lower
Lower
Lower
NON
NON
NON---HAZARDOUS
HAZARDOUS
HAZARDOUS LOCATION
LOCATION
LOCATION
HAZARDOUS
HAZARDOUS
HAZARDOUS LOCATION
LOCATION
LOCATION
Key
Key
Key for
for
for Table
Table
Table 2
2
2 and
and
and Table
Table
Table 3
3
3
A
Electrical Supply (must be sealed conduit
approved for use in hazardous locations)
B
Fused Safety Switch, with lock
C
Start/Stop Control (must be approved for
use in hazardous locations)
D
Explosion Proof Conduit Seal. Required
within 18 in. (457 mm) of the motor for the
US and Canada.
E
Fluid Pressure Gauge
F
Fluid Shutoff Valve
G
Pump Ground Wire. Two ground terminals
are provided if local code requires redundant
grounding connections.
H
Fluid Drain Valve
3A3453H
13