Troubleshooting
40
3A6941J
Troubleshooting
, page 6, before
checking or repairing the pump.
2. Check all possible problems and causes before
disassembling the pump.
Problem
Cause
Solution
Pump is not powering ON.
The red LED on the motor is not ON.
Wiring is incorrect
Polarity is wrong
Loose wire(s)
Check and verify that the wire
connections are tight.
Check and correct polarity.
Fuse is:
Wrong amperage
Not in place or missing
Faulty
Check the fuse rating and replace
with new or correct amperage fuse.
The lubrication controller is in OFF
mode.
Set the lubrication controller to the
correct lube cycle.