Setup
16
3A6941J
The auto-fill shut off (V) is used to refill the grease tank
(K) in an automatic lubrication system. When the grease
level in the tank is full, the auto-fill shut off automatically
ends the filling operation.
Always fill the tank (K) to full during refilling.
As grease is added to the tank (K), the follower plate (Y)
is pushed to the top of the tank (K) and pushes up the
valve pin (V1) which closes the inlet fluid path. Pin (V2)
pops up when the tank is full (F
. 13).
When the fluid refilling path closes, the refilling line (GG)
pressurizes and brings the remote fill station pump (AA)
to a pressurized stall condition.
Note: The operator must monitor the system during fill
-
ing of the tank to prevent any accidental fluid overflow.
Refill the Tank: Pumps with an Auto-fill
Shut Off (AFSO)
1. Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between the fill
valve (EE) and the auto-fill shut off valve (V).
2. Verify the auto-fill shut off pin (V2) is down, indicat
-
ing it is reset (F
3. Remove the dust cover (DC) from the fill coupler
(FC) on the fill valve (EE) (F
. 15).
F
IG
. 13
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture,
potentially causing serious injury. Be sure the
breather is not plugged before filling the pump.
V2
F
IG
. 14
F
IG
. 15
V2
Pin Down
EE
DC
FC
FF
Summary of Contents for Dyna-Star 3A6941J
Page 11: ...Installation 3A6941J 11 Typical Wiring Single Line Parallel Systems FIG 7...
Page 30: ...Maintenance 30 3A6941J 35 Remove the check valve and o ring 37 FIG 49 FIG 49 37...
Page 44: ...Parts 44 3A6941J 43 42 41 58 59 52 55 56 57 54 47 48 49 50 51 53...
Page 51: ...Mounting Dimensions Stand Alone Pump 3A6941J 51 Mounting Dimensions Stand Alone Pump...