Troubleshooting
3A7526B
55
System does not dispense or
dispenses in the incorrect
amount/mode
Signal error between platform and
PR-X control box
1. Verify signal was correctly sent and
received.
2. Verify signal cable is correctly
connected.
Wrong “Dispense mode”
Choose correct mode
Wrong “Dispense type”
Choose correct type
Wrong mode and/or type trigger
method
Choose correct trigger method in “Setup”
menu (job can be trigged by outside signal
or manually)
Incorrect pressure value
Loose pressure sensor cable or
adapters
Exchange cable, tighten adapters
Pressure sensor error
Replace pressure sensor
Pressure sensor signal incorrect
Calibrate pressure sensor
Problem
Cause
Solution