HMI Display Operation and Identification
24
3A7526B
Input signals status
The input signals display shows the current signal status
from customer inputs.
•
Rate CMD
-
If ‘distributed IO’ is selected as ‘Other CMD
Resource’ on
page 38, the input voltage signal will be shown
as 0-10.0, where 0 means 0 voltage, 10.0
means 10
V.
-
If ‘Gateway’ is selected as ‘Other CMD
Resource’ on
page 38, the input data sent by Profinet will be
shown as a value from 0 to 1000.
NOTE:
The Gateway option is only included in the
Profinet communication mode. Any PR-X system can be
converted to use Profinet communication mode. Order
SD card 18C277 and perform
Profinet Communication Mode Only)
Output signals status
The output signals display shows the current signal
status from the PR-X control box.
I/O communication
mode
Profinet communication
mode
Error
code
Port
code
Error
Type
Comment
0
00000
----
No Error
1
00001
Error
Estop
2
00010
Error
Lowest limit has been reached
3
00011
Error
Highest limit has been reached
4
00100
Error
Pre-charge time out
5
00101
Error
Pressure relief time out
6
00110
Error
Reload time out
7
00111
Error
Servo fault
8
01000
Error
Part A Supplier is in low level
9
01001
Error
Part B Supplier is in low level
10
01010
Error
Part A pressure exceeds system
limit
11
01011
Error
Part B pressure exceeds system
limit
12
01100
Error
Part A/B pressure is not
balanced
13
01101
Error
Servo unit lost power
14
01110
Error
Inlet valve A does not turn on in
time
15
01111
Error
Inlet valve B does not turn on in
time
16
10000
Error
Dispense valve does not turn on
in time
17
10001
Error
Inlet valve A does not turn off in
time
18
10010
Error
Inlet valve B does not turn off in
time
19
10011
Error
Dispense valve does not turn off
in time
20
10100
Error
Pressure relief fault
21
10101
Error
Pre-charge fault
22
10110
Error
Homing fault
23
10111
Error
Motor torque is over limit
24
11000
Error
Motor peak torque is over limit
25
11001
Deviation Illegal setting
26
11010
Deviation Illegal command
27
11011
Deviation Home is lost
28
11100
Deviation Reload is requested (System is
in job) or metering tube pump is
empty (System is not in job)
29
11101
Deviation Purge is requested
30
11110
Deviation Automatic relief after idle
31
11111
Deviation In system relieving