Troubleshooting
3A7526B
53
Troubleshooting
1. Follow
before checking or repairing the system.
2. Disconnect AC power from the system.
Problem
Cause
Solution
Display module completely
dark
No power
Verify AC power switch (BM) is ON
Thrown breaker
Check machine breakers and reset
Loose connection
Tighten screen data cable
Bad display module
Replace display module
No or incorrect amount of
material dispensed from
either side
MD2 Dispense Valve (AE) closed
Verify supply air pressure
Needle or Static Mixer Package
(AH) clogged
Replace needle or Static Mixer Package
(AH)
Supply pump ball valve closed (if
installed)
Open ball valve
Cartridge or pail empty
Exchange cartridge or pail
Supply pump clogged
Clean supply pump
Air in PR-X machine
Purge and prime the system
Significant material leaking
from pump seal
Pump shaft and/or shaft seal worn
Remove pump shaft assembly and reinstall
pump rebuild kit
Material weight incorrectly
dispensed
Needle or Static Mixer Package
(AH) clogged
Replace needle or Static Mixer Package
(AH). Incorporate purge timer or decrease
purge timer delay to prevent Static Mixer
Package (AH) blockage
MD2 Dispense Valve (AE) or fluid
lines clogged
Clean MD2 Dispense Valve (AE) or fluid
lines
MD2 Dispense Valve (AE) opened
or closed incorrectly
1. Verify MD2 Dispense Valve’s (AE) inlet
air pressure.
2. Inspect MD2 Dispense Valve (AE) air
cylinder and adapters for leaks.
Input air reduced or removed
Reconnect input air line to system. Increase
air pressure regulator adjustment
Inlet Valve (AL or AM) not closed (if
installed)
1. Inspect the Inlet Valve (AL or AM) for
wear and tear.
2. Verify rotary cylinder inlet pressure.
Inlet 1K Ultra-Lite valve leaking (if
installed)
Inspect needle and seal components
Piston worn out or broken
Replace piston