HMI Display Operation and Identification
3A7526B
31
Supply system operation
•
Part A or B feed: Activate to start or stop supply
device A or B, regardless of supply type (supply
pump feed or cartridge feed).
•
Part A or B smart feed: Only activate to drive supply
device in reloading.
-
For supply pump feed, the system will start the
pump only while reloading.
-
For cartridge feed, the piston is only active in
reloading. When the system is dispensing, the
piston is in a neutral position.
•
Cart change: Only activate to change cartridge after
the job is finished. Select ‘Cart Change” to move
back the cartridge cylinder rod. Press ‘F3’ to move
forward the cartridge cylinder rod.
Setup Screen
Setup Screen 1 - Reload
On the Reload Setup Screen, press ‘F1’ or select the
button to display the System Main Screen. Press
‘F2’ or select the
button to return to the previous
screen. Press ‘F4’ or select the
button to continue to
the next screen.
The content and functions of this screen are as follows:
Reload speed setup
Set both the reloading speed and ‘Home' operations
speed.
To prevent injury from moving parts, make sure the
cartridge change is completed before pressing ‘F3’ to
resume feed.
F
IG
. 22 Reload Setup Screen
Summary of Contents for 25R128