HMI Display Operation and Identification
38
3A7526B
Advanced Setup Screen 2
On the Advanced Setup Screen 2, press ‘F1’ or select
the
button to display the System Main Screen.
Press ‘F2’ or select the
button to return to the
previous screen. Press ‘F4’ or select the
button to
continue to the next screen.
The content and functions of this screen are as follows:
Mode selected by
Options for mode selection input include Display,
Distributed IO or Gateway.
•
If ‘Distributed IO’ or ‘Gateway’ is selected, in
Automatic mode, the shot or bead working mode
(Sequence mode will be inaccessible) must be
controlled by customer signals. The operator will not
be able to change working mode using the touch
screen.
•
If ‘Display’ is selected, working mode will include
Shot, Bead and Sequence mode. The operator will
be able to change working mode using the touch
screen.
Style No. selected by
The operator may choose whether the style number
may be changed by Display, Distributed IO or Gateway.
Dispense CMD resource
The operator may choose whether the Dispense
Command (CMD) resource comes from Distributed I/O
communication or Gateway (Profinet) communication.
Display option is unavailable.
Other CMD resource
The operator may choose whether the Other Command
(CMD) Resource comes from Distributed I/O
communication or Gateway (Profinet) communication.
Display option is unavailable.
Other command (CMD) includes job start, reload, purge
start, remote reset.
NOTE:
The Gateway option is only included in the
Profinet communication mode. Any PR-X system can be
converted to use Profinet communication mode. Order
SD card 18C277 and perform
Profinet Communication Mode Only)
on page 47.
F
IG
. 31
Advanced Setup Screen - 2 (I/O
Communication Mode)
F
IG
. 32
Advanced Setup Screen - 2 (Profinet
Communication Mode)
Summary of Contents for 25R128