Structure for the installation
The structural design and construction for the display installation is the customer’s or its installer’s responsibility. GPO Display does not take
any responsibility on design or construction of installations. The minimum requirements for space, strength of the structure, electronic, heat
dissipation and environmental condition is described in this manual. If any further information or support is needed from GPO Display, please
contact us in advance to ensure ample time for support. We will be glad to help with any recommendations or information.
Call 510-659-9855 x1 or e-mail
.
Power Requirements
Please refer to the specifications for power consumption of displays to be installed. Do not plug more than two units into a given receptacle
(example: all displays in 2x2 should not be plugged into quad receptacle. Using more than 70% of current on the AC circuit is strongly
discouraged. Clean AC power is required for “noiseless” screen images. Avoid damages inflicted by power glitches or surges- either a power
conditioner or surge protector is recommended. Contact your electric power specialist for consultation.
Heat Dissipation Requirements
The range of LCD operational conditions are:
Temperature:
32
°
F
~
104
°
F
Humidity :
20
~
80%
-Consult with the display user manual for BTU ratings.
7
Chapter 2 Preparations
GPO Display Wall Mounts
Model
Dimension (W x H x D, inch)
Weight
ZLM46T
40.24 x 22.7 x 2.13
25lbs
HLM46TE
40.16 x 22.63 x 2.13
25lbs
HLM49T
42.42 x 23.93 x 2.13
30lbs
HLM49TE
42.35 x 23.86 x 2.13
30lbs
HLM55T
47.76 x 26.93 x 2.13
37lbs
HLM55TE
47.7 x 26.86 x 2.13
37lbs
GDSVW775
21.25 x 21.25 x 3.9 to 14.02"
28lbs
Product Description
Verify wall mount model name and check dimensions and weight.