5.4.1.3 Install the Radial Heat Flinger (As required)
Figure 28: Install the Air Cooling Package - Radial heat flinger
1.
Remove the standard INPRO seal bearing isolator (123) and replace with INPRO radial heat flinger
(123B). Refer to
6.6.1 Assemble the power end on page 92
5.4.2 Bearing lubrication
Precautions
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation.
Ensure bearings are properly lubricated prior to startup.
Pumps are shipped without oil
You must lubricate oil-lubricated bearings at the job site.
Ring oil lubrication
Ring oil-lubricated bearings are standard. Bearing housings are supplied with constant-level oilers and
sight glasses. Make sure that oil ring properly seated in the grooves in the shaft.
5.4 Couple the pump and driver
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual
51