122
184
Figure 75: Seal-chamber lock (register) runout
6.6.4 Install the cartridge-type mechanical seal and seal-chamber cover
NOTICE:
Refer to the mechanical seal manufacturer’s drawings and instructions for assistance during
the installation of the mechanical seal.
1.
Remove the impeller.
a) Loosen and remove the impeller nut.
The impeller nut has left-hand threads.
b) Remove the impeller, impeller key, and seal-chamber cover (184) as described in the Disas-
sembly section.
2.
Lubricate all O-rings with suitable lubricant, unless the seal manufacturer’s instructions indicate oth-
erwise.
3.
Slide the cartridge seal assembly (rotary, stationary gland, gland gasket, and sleeve) onto the shaft
(122).
NOTICE:
Ensure that the mechanical-seal gland-piping connections are properly oriented.
6.6 Reassembly
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual
105