If the total indicator reading is greater than the values shown in this table, determine the cause and
correct it.
Table 12: Maximum Allowable Seal Chamber Face Runout
Group
Maximum Allowable Total Indicator Reading
13i, 14i, 24i, 25i, 35i
0.05 mm | 0.002 in.
36i
0.065 mm | 0.0026 in.
47i
0.07 mm | 0.0028 in.
58i
0.08 mm | 0.0031 in.
122
184
Figure 74: Seal-chamber face runout
9.
Check the seal-chamber lock (register) runout:
a) Mount a dial indicator on the shaft or shaft sleeve.
b) Rotate the shaft so that the indicator rides along the seal-chamber lock (register) for 360°.
If the total indicator reading is greater than 0.125 mm | 0.005 in., determine the cause and correct it.
6.6 Reassembly
104
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual