![Gotting HG G-98780-A Device Description Download Page 33](http://html1.mh-extra.com/html/gotting/hg-g-98780-a/hg-g-98780-a_device-description_2247542033.webp)
Device Description HG G-98780-A | English, Revision 16 | Date: 15.07.2021
33
Software – Chapter 6
Using „(
)isplay Telegram Content“ it is possible to check the generated telegram
(refer to Figure 17 on page 33). In this example the mask has the value 0xff. Press
any key to return to the menu
Serial Output
.
Figure 17
Output „(D)isplay Telegram Content“
The parameter “(
)har Delaytime“ is the so-called character delay for procedure
3964R (refer to appendix, section 10.6 „Procedure 3964R“ auf Seite 49) and the time
out period for incoming characters for the transparent procedure (refer to appendix,
section 10.7 „Procedure „transparent““ auf Seite 50).
either activates the permanent output, according to the
Clock for Sampling
set in Time&Code (
1
; refer to 6.2.2.2 on page 31), or generates the output solely
when a transponder is decoded within the reading range of the antenna (
0
).
With
the repetition rate of the serial output is set.
S:0547 X:+0000 Code: 00000000 Read: 0
U[/mV]:24200 I[/mA]: 140 T[Grd.C]:+28 E: 0200 N: 0
Ftx[/Hz]:105960 Prog_Code: 00000000
STX 1 Bytes from Position: 1
CODE 4 Bytes from Position: 2
SUM_1 2 Bytes from Position: 6
Vcc 1 Bytes from Position: 8
Current 1 Bytes from Position: 9
Temp. 1 Bytes from Position: 10
CodesRd 2 Bytes from Position: 11
Status 2 Bytes from Position: 13
(Q)uit Menue