Device Description HG G-98780-A | English, Revision 16 | Date: 15.07.2021
31
Software – Chapter 6
Other menus are activated by pressing the (characters in brackets). Before altered
values are transferred into the permanent memory, the pass word
815
has to be en
-
tered by pressing
. This prevents unintended alterations of values. With
the val
-
ues are saved after their alteration and input of the password.
System status are explained in plain text upon pressing
. Typing
deletes the er
-
ror display. Quit the menu by pressing
.
The following sections describe one by one the menus
(
)ime & Code (section 6.2.2.2 on page 31)
(
)erial Output (section 6.2.2.3 on page 32)
C(
)N Parameters (section 6.2.2.4 on page 34)
P(
)ofibus-Parameters (section 6.2.2.5 on page 35)
CS(
) (section 6.2.2.6 on page 36)
(
)oot Load (section 6.2.2.7 on page 36).
(
)uit Monitor. With
the monitor program is left, whenever the serial proce
-
dures 3964R or transparent are active. In procedure ’Monitor only’ it is impossi
-
ble to leave the monitor program.
6.2.2.2 (T)ime & Code
This menu enables the setting of timing values for the transponder decoding, the po
-
sition calculation and the positioning pulse.
Figure 15
Menu: (T)ime & Code
With
the voltage threshold S for the release of the output of the positioning pulse
is set in order to eliminate wrong outputs.
With
the voltage threshold S for the start of the code decoding is set in order to
prevent decoding tries during a weak signal period.
With
it is possible to switch on the reference transponder for testing.
The duration of the positioning pulses can be set in a millisecond pattern by pressing
.
S:0544 X:+0000 Code: 00000000 Read: 0
U[/mV]:24000 I[/mA]: 150 T[Grd.C]:+28 E: 0200 N: 0
Ftx[/Hz]:105970 Prog_Code: 00000000
(L)evel for Positioning [10.1023]: 256
(T)hreshold Decoding [10.1023]: 256
(1) switch Reference Transponder: 0
(P)osi-Pulse Time [n*1ms]: 100
(Q)uit Menue