activates the remote operation. In this case (independent of the settings of
Con-
tinuos Telegrams
) telegrams are no longer generated, but only remote frames with
the corresponding address are answered.
offers the option to ’freeze’ the output for 0 to 20 telegrams, i. e. the values at the
time of the positioning pulse output are preserved.
The CAN status register is displayed in the uppermost line of the menu. This informa-
tion may be used for simple diagnosis.
5.3.2.6
Cs(v)
For diagnosis, it is possible to start the output of the values
Code
,
U
Sum
,
U
Dif
,
Y-Pos
,
X-Pos
, the states
Transponder within range
,
Code OK
,
Positioning pulse
(also refer to Table 3 on page 20), number of code readings (
Read
), number of code
reading failures (
N
) and in addition a telegram counter in
CSV format
(Comma Sepa-
rated Values; especially for processing text files with programs for table calculation).
Data output is carried out with 38.400 Bd, 8 bit and even parity, until it is terminated by
pressing any key. Following the pressing of a key, a reset is generated and the Antenna
is re-set to its original condition (not monitor mode) including the saved parameters.
The CSV output could e. g. be saved using the program HyperTerminal® (also refer to
section 5.1 on page 30). To do so, use the function
record text ...
of menu
Transmission
and insert a file name (this file name should have the ending
.csv
, in
order to enable the table calculation program to automatically detect this file later).
Once the file has been recorded and closed under HyperTerminal®, it may be loaded
into a table calculation program (e. g. Microsoft® Excel®, Sun® StarCalc®, ...).
When opening the file, the table calculation program prompts various options. Select
the option that indicates that this file consists of comma separated values. Then the
data may be processed as diagrams or recorded as native table calculation file for
transmission.