CAN Interface
English, Revision 01, Date: 14.04.2009
31
7.4.4.17 Manufacture Parameter - parameters of the antenna
After switching the frequencies, the corresponding detect bit ( bit 6 / bit 7) is deleted
for 40 ms in the status (see Table 6 on page 19).
Index
Sub Index
Name
Typ
Attr
Map
Default
Meaning
0x2000
00
number of
parameter
Unsigned 8
RO
No
0x08
number of sub
indexes
01
Frequency 1
Unsigned 16
RW
Yes
10000
Frequency chan-
nel 1 in Hz
02
Frequency 2
Unsigned 16
RW
Yes
10000
Frequency chan-
nel 2 in Hz
03
Threshold
CD 1 LED
Unsigned 16
RW
No
1000
threshold for
Us1, after exeed-
ing LED CD1 is lit
04
Threshold
CD 2 LED
Unsigned 16
RW
No
1000
threshold for
Us2, after exeed-
ing LED CD2 is lit
05
Height of
Ant 1
Unsigned 8
RW
No
60
distance guide
wire - casing -
bottom antenna 1
in mm
06
Height of
Ant 2
Unsigned 8
RW
No
60
distance guide
wire - casing -
bottom antenna 2
in mm
07
Internal
Height of
Ant1
Unsigned 8
RW
No
35
distance induc-
tor system - cas-
ing - bottom
antenna 1 in mm
08
Internal
Height of
Ant2
Unsigned 8
RW
No
35
distance inductor
system - casing -
bottom antenna 2
in mm
Table 30