Calibration menu
The calibration menu (here: antenna 1) is made up as follows:
Figure 5
Screenshot: calibration menu antenna 1
During the calibration the maximum of the voltage
S1
is saved in
Us1
. In
Udl1
and
Udr1
the maximum of the voltage
D1
on the left and right side from the wire is saved.
During this procedure the sensor has to be moved e.g. ±120 mm above the wire if the
reading height is 60 mm. This equals a value of reading height multiplied with two. Af-
ter pressing any key the calibration values are calculated using the maxima and the
reading heigt, which was entered in the antenna menu. To save this values permanent-
ly
L
has to be pressed in the main menu.
6.1.3
CAN menu
The CAN menu is made up as follows:
Figure 6
Screenshot: CAN menu
S1: 3780 D1: 3617 S2: 3133 D2: 4590 X1: +62 X2: +99 Status: 0xc0
Us1: 3795 Udl1: 0 Udr1: 3645
shift Antenna 1 from -2*H to +2*H and press any key when ready
S1: 0 D1: -6 S2: 0 D2: -40 X1: -256 X2: -256 Status: 0x00
Bus online Operational Last Err: 0000
(N)ode ID [1..127]: 1
CAN-(B)audrate[20,50,125,250,500,800,1000 kB]: 500
(C) TPDO_1 mode [1..240,255]: 255
(D) TPDO_1 inhibit time [0,10..10000 ms]: 0
(E) TPDO_1 event time [0,10..10000 ms]: 10
(F) TPDO_2 mode [1..240,255]: 255
(G) TPDO_2 inhibit time [0,10..10000 ms]: 0
(H) TPDO_2 event time [0,10..10000 ms]: 10
(I) Heartbeat time [0..65535 ms]: 0
(A)utostart 1
(L)owbyte first 0
(Q)uit