8
MDE-LEDI-NETWORK-TDS-4099V1.0
3. SETTING
UP THE SERVER,
GENERAL INFORMATION
3.1. MANUAL NETWORK CONFIGURATION
By default, the server obtains its IPv4 and IPv6 addresses from a DHCP server.
There are several ways to manually modify IPv4 and IPv6:
►
By accessing the web interface, in the « Network » page. (See section 5.2.3. “Page
Network")
►
By using the front buttons (See section 4.4.2. “IPv4" )
►
By using the Telnet and SSH consoles (See section 5.2.9. “INTERFACE page")
Additionally, the server will automatically take an IP address in the 169.254.0.0/16 and
fe80::/10 pre-defined scopes. The IP addresses of the LEDI
®
NETWORK TDS V1 can be
displayed at any time by pressing any of the arrow keys on the front panel.
3.2. OUTPUT CARDS CONFIGURATION
The default configuration for all the output cards is to deliver UTC time and only when the
server is synchronized.
For most of the output boards, it is possible to modify the output time code format, time
zone and DST policy.
These settings can be modified in section 5.2.8. "Output Page".
3.3. ALARMS SETTINGS
►
The LEDI
®
NETWORK TDS V1 has an embedded alarm system than can alert the
administrators in case of need.
►
The LCD front screen displays the current alarms messages and its backlight blinks to
indicate that at least one alarm condition is happening.
►
SNMP traps can be sent to one or several supervision stations.
►
The server can send e-mails with details on the situation.
►
The server can send Syslog frames to one or two servers.
►
Le serveur peut envoyer des trames Syslog à un ou deux serveurs.
These three features can be configured in the « SNMP » and « Alarm » webpages (See
sections 5.2.4. “ALARMS Page" and 5.2.5. “SNMP page").