Updating via the SSH interface
For this procedure, the SSH interface must be activated in the device’s settings.
1- Open a terminal (Start menu -> Execute ->"
cmd
")
2- Type "
pscp <firmware paht> root@<module IP address>:/"
, ENTER
If pscp is unavailable, please install the Putty package from the
https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html
web page then restart step 2
Password: "
gtmt
"
3- Do not turn off the module before rebooting is complete.
Please read the “WARNINGS” note carefully
☛
WARNINGS
More specifically, do not interrupt the product’s functioning or reboot it during
the updating process. The device will reboot on its own when required.
Please also make sure to secure the power source(s) before and during the
update.
The product can be used again when the Web pages can be loaded again in the
browser and the Up Time information displayed in the Index page is superior to
1 minute.
During the update, the product will reboot once or twice. The reboots trigger the
reset of the Up Time. Therefore the value displayed in the Index page must be
coherent with that information.
When in doubt, please wait 5 minutes before rebooting the product. That
duration corresponds to the approximate time needed for two secured reboots
of the product following an update.
Ignoring the recommendations above may result in corrupting the network
cards (NTP output cards or main/management Ethernet port). The related
repairs will be billed and are not covered by the warranty.