GDS-15-PH 0519
7
pH
Controller
(DS-03)
Overfill Alarm
Lamp
Cleaning In
Progress Lamp
Main Circuit
Breaker
Main Pump
Power Switch
Chemical
Pump Lamp
Main Power
Lamp
CONTROL PANEL
Power Lamp
• The POWER LAMP is lit whenever the unit is plugged in and the GFCI is reset. It
indicates that power is present at the unit.
Main Pump Power Switch
• The MAIN PUMP POWER SWITCH controls the main recirculation pump. This
switch must be in the “ON” position (up) for normal recirculation operation.
Circuit Breaker
• The CIRCUIT BREAKER is a fast-acting resettable 15 amp circuit breaker that
protects the unit’s electrical components from surges or short circuits.
• If the circuit breaker trips, wait a few seconds then depress the button to reset.
If the breaker keeps tripping, unplug unit and call Goodway at once.
Chem Pump Lamp
• The CHEM PUMP LAMP is lit whenever the chemical pump is injecting chemical
into the descaling system.