Filling a Closed Vessel with ScaleBreak®
1.
Refer to the
ScaleBreak®
Usage Manual for the required amount of
ScaleBreak®
.
2.
You can use the
Venting Drum
and
Main Pump
to fill a closed vessel:
2a. After the unit is primed, remove the lid and fill the
Venting Drum
up to
the bottom of the Overfill Sensor with
ScaleBreak®
. The white Overfill
Sensor float should not be submerged.
2b. Make sure
Valve #1
and
Valve #3
are open.
2c. Make sure
Valve #2
is closed.
2d. Turn the
Main Pump
Switch On and empty the
Venting Drum
into
the vessel.
2e. When the
Venting Drum
is empty, turn
Main Pump
Off, add more
ScaleBreak®
into the Venting Drum, and repeat operation.
3.
After all the
ScaleBreak®
has been added, fill the
Venting Drum
with about 5
gallons (19 L) of water (to the elbow of the Overfill Sensor).
4.
Fill the vessel to be cleaned with water. For normal cleaning use a ratio of 70%
water to 30%
ScaleBreak®
.
5.
You can use the
Venting Drum
and
Main Pump
to fill a closed vessel with water.
Use the method above.
6.
If the total volume of the closed vessel is less than 15 gallons (56.7 L), you can
just fill the vessel with water, place the Chemical Pickup Hose in a 5 gallon
chemical bucket or drum, and clean the unit using the “Auto” mode on the
pH Controller
.
a. Make sure the Venting Drum is only full up to the elbow of the Overfill
Sensor. This will allow the maximum amount of
ScaleBreak®
to be added
to the closed vessel system.
7.
If the total volume of the vessel is more than 15 gallons (56.7 L), you can use
the method above, or you can use the on-board chemical pump:
7a Once the Main Pump and Chemical Pump are primed and the unit is
hooked up to the vessel being cleaned, make sure the Chemical Pickup
Hose is in the chemical bucket or drum
7b. Slide the pH Controller Switch to “ON”.
7c. Once the required amount of
ScaleBreak®
has been added to the vessel,
slide the pH Controller Switch to “OFF”
8.
Fill the vessel with water. For normal cleaning use a ratio of 70% water to
30%
ScaleBreak®
.
Filling an Open Vessel with ScaleBreak®
1.
Refer to the
ScaleBreak®
Usage Manual for the required amount
of
ScaleBreak®
.
2.
Pour the required amount of
ScaleBreak®
into the open vessel.
3.
After the
ScaleBreak®
has been added, fill the open vessel with water. For
normal cleaning use a ratio of 70% water to 30%
ScaleBreak®
.
4.
Fill the open vessel ½ way with water. Allow enough room for the introduction
of
ScaleBreak®
.
5.
Place the Chemical Pickup Hose in the chemical bucket or drum.
6.
The system is now ready for automatic operation. Turn
Main Pump
On
(up position) and slide
pH Controller
Switch
to
“Auto”