background image

147

Main

  Place this power supply
  as closest as possible
  to the first distributor.

   Take off JP1 jumper
   of all the distributors
   except in the last one.

148

IMPORTANT: 

For this type of installation, the door panels must have plugged an EL560 

                       module in each and the monitors must have an EL

plugged in each.

562 

1,00mm²

2,50mm²

0,25mm²

0,25mm²

CAT-5

CAT-5

Terminal

SECTIONS CHART

50m.

Distance

150m.

A , A , A, D

in

out

V

, V

, V , M

in+,-

out+,-

p,d

p,d

+, 

–, CV+, CV–

For longer distances than the specified contact with your distributor.

ideo installation without coaxial cable 

and Plus/Uno monitors.

v

The installation diagram shows the connection of a video system with one or several door
     panels for the same building.
If the system has one door panel only, override the wiring to the second door panel.
If the system has more than one door panel, wire the second panel as shown on the
     diagram. In case of more than two door panels, wire them as the second is connected.

Remember

:

 if the installation has Uno telephones or monitors 

a resistor must be         

installed between 'D' and '–' terminals of the door panel

. In case of several 

door panels place the resistor 

only

 on the one closest to the backbone. When using 

digital repeater 

RD-Plus/Uno SE

, this operation is not necessary.

If the distance between the door panel and the last monitor or telephone exceeds 200 meters, or 
if the building has more than 200 monitors or telephones, a digital repeater 

RD-Plus/Uno SE 

will be necessary, (see page 160).

A

out

D

+

-

CV

+

CV

-

Remember

:

 if the installation has Uno telephones or monitors 

a resistor must be         

installed between 'D' and '–' terminals of the door panel

. In case of several 

door panels place the resistor 

only

 on the one closest to the backbone. When using 

digital repeater 

RD-Plus/Uno SE

, this operation is not necessary.

If the distance between the door panel and the last monitor or telephone exceeds 200 meters, or 
if the building has more than 200 monitors or telephones, a digital repeater 

RD-Plus/Uno SE 

will be necessary, (see page 160).

680

W

*

Main

FA-Plus/C or FA-Plus

SEC

PRI

~

~

+ +

-

-

JP1

CV+

CV-

D

Malla

V

in-

A

in

A

out

V

in+

V

out-

V

out+

+

-

JP

4

3

2

1

CN1

CN2

V

p

M

p

A D

_

+

EL562
JP1

V

p

M

p

A D

_

+

EL562
JP1

V

p

M

p

A D

_

+

EL562
JP1

V

p

M

p

A D

_

+

EL562
JP1

1

4

7

2
5

8

3

6 0

9

C

JP1

A

A

D

D

CT1

+

+

V

pi

V

d1

M

pi

M

d1

_

_

A

D

+

V

d6

M

d6

_

A D

+

V

po

M

po

_

D6L-Plus/2H

SALIDA

ENTRADA

CT6

A

A

D

D

CT1

+

+

V

pi

V

d1

M

pi

M

d1

_

_

A

D

+

V

d6

M

d6

_

A D

+

V

po

M

po

_

D6L-Plus/2H

SALIDA

ENTRADA

CT6

680

W

 Platea Uno/

Tekna Uno

 Platea Plus/

Tekna Plus

 Platea Plus/

Tekna Plus

 Platea Uno/

Tekna Uno

CV+

CV-

D

Malla

V

in-

A

in

A

out

V

in+

V

out-

V

out+

+

-

JP

4

3

2

1

CN1

CN2

1

4

7

2
5

8

3

6 0

9

C

FA-Plus/C

rev.938072

SEC

PRI

+

+

-

-

230 110 0

*

INSTALLATION DIAGRAMS

ONE OR SEVERAL ACCESSES DOORS

 

=Master.

S  =Slave.

M

S

Access door panel

 Access door panel

Summary of Contents for 50124319

Page 1: ...Stadio Plus Instructions manual Audio and Video door entry system digital installation with coded panel T3403ML rev 0112 C d 50124319...

Page 2: ...to 154 Connection of an a c lock release 155 Link of several power supplies 155 Optional connections 156 to 160 Troubleshooting hints 161 Notes 162 INTRODUCTION STARTING RECOMMENDATIONS INDEX First o...

Page 3: ...ng the connector screws Install the power supply in a dry and protected place without risk of drip or water projections Avoid to place it near to heating sources in dusty locations or smoky enviroment...

Page 4: ...release push button only T 740 Plus wIntercommunication function with other monitor or telephone of the same apartment wOutput for additional call repeater wCall to slave porter s exchange wPanic cal...

Page 5: ...ctivated and the door panel display will show the message door opened O The monitor and telephone push buttons description is shown on pages 132 139 and 141 respectively Systems with general entrance...

Page 6: ...tal conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry systems avoid direct incidence from light sources reparin...

Page 7: ...OWN marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the...

Page 8: ...rection to open the door panel this selection should ease the door panel wiring The opening direction will be settled through the hinges position that must be passed through the header clips as shown...

Page 9: ...of an EL560 module plugged in the CN4 connector Factory default coaxial cable Jumper JP3 selects the volume of the door panel acknowledgement signals call in progress system busy and door opened If af...

Page 10: ...e for video installations O with twisted pair cable Plug the EL560 module in the CN6 connector The CN4 connector is accessible by unbolting the four screws of the pcb protection cover NOTE on this typ...

Page 11: ...in to adjust the telecamera position In case of low light conditions an external illumination can be activated by connecting a SAR 12 24 relay between terminals H and L2 of the sound module lose the...

Page 12: ...mming options with black text and white background are availables in both menues options with white text and black background are only availables on installer menu The first time you enter into the pr...

Page 13: ...ntrance panel configure as master one panel of each internal building Press to change this value If this panel is a general entrance door panel select YES Press to change this value Sets the building...

Page 14: ...eo and or audio communication without a previous call In buildings with several panels this function can be activated in one of them only in systems with general entrance panel this function can be ac...

Page 15: ...n to the initial screen Allows to change the installer PIN code to enter into the installer programming menu page 119 Do not let know this code to untrained people any change on the programming menu c...

Page 16: ...seconds To change this value press the display will show the message modify value Key in the new activation time and confirm by pressing If is pressed the former value will be restored The lock releas...

Page 17: ...access control feature lock release activation by entering a PIN code Press to change this value The system has three different codes to activate the lock release To change the first code press the d...

Page 18: ...0 to 23 and minutes value from 0 to 59 and confirm by pressing If is pressed the former value will be restored For a proper operation of this function the system clock must be correctly adjusted as de...

Page 19: ...age enter address key in the monitor code and confirm by pressing If the panel has been configurated as general entrance door panel a six digits code must be entered the three first digits will match...

Page 20: ...al screen Repeat this procedure to insert as much entries as it is needed Allows to modify the details of an exisiting entry Press the display will show the first repertory position in case of no exis...

Page 21: ...n finished both equipments will exit from their programming menues repertory tx sending 095 O K Allows to receive the repertory content from other panel or porter s exchange in the same installation P...

Page 22: ...bed The maximum number of characters in one text line is 16 Use the numeric keys to introduce text press several times the corresponding key till the desired character appears on the display according...

Page 23: ...and insert the wallplugs Fix the transformer with the specified screws The power supply can be installed on a DIN 46277 guide simply pressing it To disassemble the power supply from the DIN guide use...

Page 24: ...i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film only Platea Plus Function push buttons depending on the model Cord Attachment holes Identification label...

Page 25: ...n the monitor On Off 45 seconds after turning On the monitor only calls will be received If not in both models allows to call to the master porter s exchange During call reception and communication pr...

Page 26: ...Uno Locate the CN2 connector that s placed in the monitor base Remove the existing jumper on the connector and the JP1 jumper on the right then plug the EL562 NOTE On this type of installations the EL...

Page 27: ...E 11758882 Colocar la parte superior de la regleta a 1 60m del suelo Place the top part of the monitor connector at 1 60m from the floor 50mm 50mm Presionar para abrir Press to open a b b f e d c For...

Page 28: ...est object must be 5cm Place the monitor at right angles to the connector and align the attaching holes of the monitor with the attachment hooks of the connector as it is shown on the drawing Lock out...

Page 29: ...push button pressed switch on the monitor To show that the system is ready for programming the panel will reproduce a sound and the LCD will display the message program mode appearing the picture on...

Page 30: ...by pressing the door opener button during 1 second Once it has been turned off press the autoswitch on button Keep the autoswitch on button pressed and without releasing it press the door opener butto...

Page 31: ...itch Auxiliary function push button Volume control Subjection Door f h i all volume control C MAX OFF The telephone allows to regulate the call volume with a maximum medium and off value With the help...

Page 32: ...s disabled if a communication is already established PA output mode switches 1to ON and 2 to OFF Regardless of the handset s position it activates the PA telephone output C mode switches 1 to OFF and...

Page 33: ...e the telephone as shown on the picture Once the telephone is closed connect the handset using the telephone cord and put it on the cradle Avoid placing the telephone near sources of heat in dusty loc...

Page 34: ...ns Hook switch erminal connector description T HZ A D _ positive ground audio communication digital communication door bell push button input A D HZ escription of the T 740 Uno telephones D If the han...

Page 35: ...electrical embedding box or directly on the wall as shown on the picture If the telephone will be installed directly over the wall drill two holes of 6mm on the specified positions using 6mm wallplug...

Page 36: ...m as slaves both monitors or telephones To programm the telephone as Slave press the P1 door release push button the telephone led will quick blink and later press the hook switch the led will off Clo...

Page 37: ...then put down the handset Enter the code that will be used to call to this telephone and press the key At this moment the panel and the telephone handset will reproduce a sound To show that the syste...

Page 38: ...lus SEC PRI CV CV D Malla Vin Ain Aout Vin Vout Vout CN1 CN2 JP 4 3 2 1 A _ D Malla Vin Vout CN4 A _ D Malla Vin Vout CN4 D4L PLUS IN D1 D2 CTin JP1 OUT 1 4 7 2 5 8 3 6 0 9 C Platea Plus Tekna Plus 68...

Page 39: ...ng a digital repeater RD Plus Uno SE this operation is not necessary If the distance between the door panel and the last monitor or telephone exceeds 200 meters or if the building has more than 200 mo...

Page 40: ...Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 1 4 7 2 5 8 3 6 0 9 C JP1 A A D D CT1 Vpi Vd1 Mpi Md1 _ _ A D Vd6 Md6 _ A D VpoMpo _ D6L Plus 2H SALIDA ENTRADA CT...

Page 41: ...r panel In case of several door panels place the resistor only on the one closest to the backbone When using a digital repeater RD Plus Uno SE this operation is not necessary If the distance between t...

Page 42: ...he first telephone FA Plus C or FA Plus SEC PRI A A _ _ D D A _ D T 740 Plus A _ D CV CV D Malla Vin Ain Aout Vin Vout Vout JP 4 3 2 1 CN1 CN2 T 740 Uno 680W T 740 Plus T 740 Plus 1 4 7 2 5 8 3 6 0 9...

Page 43: ...using a digital repeater RD Plus Uno SE this operation is not necessary If the distance between the door panel and the last monitor or telephone exceeds 200 meters or if the building has more than 20...

Page 44: ...PLUS 1 4 7 2 5 8 3 6 0 9 C OUT CTin D1 JP1 IN FA Plus C rev 938072 SEC PRI 230 110 0 SW1 SW2 FA Plus or FA Plus C SEC PRI Main Inner door panel EL500 mode M BACKBONE 1 D Malla Vin Ain Aout Vin Vout Vo...

Page 45: ...N1 CN2 JP 4 3 2 1 D4L PLUS 1 4 7 2 5 8 3 6 0 9 C OUT CTin D1 JP1 IN FA Plus C rev 938072 SEC PRI 230 110 0 S General door panel SW2 SEC PRI FA Plus or FA Plus C Main SW1 EL500 mode M BACKBONE 2 Inner...

Page 46: ...door panels and up to 127 internal building door panels backbone building In case of more than two general entrance door panels wire them as the second is connected In video systems use a D4L Plus dis...

Page 47: ...Uno is connected to an internal building door panel a digital repeater RD Plus Uno SE must be used installed as shown in the diagram for the configuration of the RD PLUS UNO SE see the TRD PLUS UNO SE...

Page 48: ...to the positive terminal of its corresponding power supply To wire several power supplies link their ground terminals NEVER link positive terminals of different power supplies To the door panel to th...

Page 49: ...will be wired through the relay contacts SAR 12 24 the maximum current for stairs light will be 1 8A To distributor door panel To stairs light push button Lock release Vac TF 104 Main PRI SEC SAR 12 2...

Page 50: ...ng the call is in progress or that the other unit is communicating with the door panel To establish communication lift the handset of the called unit If during an intercom communication a call is made...

Page 51: ...ith no dependence of the handset position If this device is shared for all monitors link their 2C terminal and use just one relay unit In case that each monitor has its own camera use a SAR 12 24 rela...

Page 52: ...ndence of the handset position Usual applications are the activation of stairs light second lock release First t T 740 Plus telephone must be configured with SW1 dip switch in PA output mode function...

Page 53: ...Plus Uno SE should be installed A _ D Malla Vin Vout CN4 A _ D Malla Vin Vout CN2 A _ D Malla Vin Vout CN4 D4L PLUS D4L PLUS Platea Plus Tekna Plus Platea Uno Tekna Uno Platea Plus Tekna Plus IN D1 D2...

Page 54: ...ommunication progresses w Disconnect the lock release from door panel terminal connector and short circuit terminals and CV at that moment the output voltage between terminals CV y CV should be 12Vd c...

Page 55: ...NOTAS NOTES 162...