147
Main
Place this power supply
as closest as possible
to the first distributor.
Take off JP1 jumper
of all the distributors
except in the last one.
148
IMPORTANT:
For this type of installation, the door panels must have plugged an EL560
module in each and the monitors must have an EL
plugged in each.
562
1,00mm²
2,50mm²
0,25mm²
0,25mm²
CAT-5
CAT-5
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in
out
V
, V
, V , M
in+,-
out+,-
p,d
p,d
+,
–, CV+, CV–
For longer distances than the specified contact with your distributor.
ideo installation without coaxial cable
and Plus/Uno monitors.
v
The installation diagram shows the connection of a video system with one or several door
panels for the same building.
If the system has one door panel only, override the wiring to the second door panel.
If the system has more than one door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
Remember
:
if the installation has Uno telephones or monitors
a resistor must be
installed between 'D' and '–' terminals of the door panel
. In case of several
door panels place the resistor
only
on the one closest to the backbone. When using
a
digital repeater
RD-Plus/Uno SE
, this operation is not necessary.
If the distance between the door panel and the last monitor or telephone exceeds 200 meters, or
if the building has more than 200 monitors or telephones, a digital repeater
RD-Plus/Uno SE
will be necessary, (see page 160).
A
out
D
+
-
CV
+
CV
-
Remember
:
if the installation has Uno telephones or monitors
a resistor must be
installed between 'D' and '–' terminals of the door panel
. In case of several
door panels place the resistor
only
on the one closest to the backbone. When using
a
digital repeater
RD-Plus/Uno SE
, this operation is not necessary.
If the distance between the door panel and the last monitor or telephone exceeds 200 meters, or
if the building has more than 200 monitors or telephones, a digital repeater
RD-Plus/Uno SE
will be necessary, (see page 160).
680
W
*
Main
FA-Plus/C or FA-Plus
SEC
PRI
~
~
+ +
-
-
JP1
CV+
CV-
D
Malla
V
in-
A
in
A
out
V
in+
V
out-
V
out+
+
-
JP
4
3
2
1
CN1
CN2
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
1
4
7
2
5
8
3
6 0
9
C
JP1
A
A
D
D
CT1
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
+
V
d6
M
d6
_
A D
+
V
po
M
po
_
D6L-Plus/2H
SALIDA
ENTRADA
CT6
A
A
D
D
CT1
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
+
V
d6
M
d6
_
A D
+
V
po
M
po
_
D6L-Plus/2H
SALIDA
ENTRADA
CT6
680
W
Platea Uno/
Tekna Uno
Platea Plus/
Tekna Plus
Platea Plus/
Tekna Plus
Platea Uno/
Tekna Uno
CV+
CV-
D
Malla
V
in-
A
in
A
out
V
in+
V
out-
V
out+
+
-
JP
4
3
2
1
CN1
CN2
1
4
7
2
5
8
3
6 0
9
C
FA-Plus/C
rev.938072
SEC
PRI
+
+
-
-
230 110 0
*
INSTALLATION DIAGRAMS
ONE OR SEVERAL ACCESSES DOORS
M
=Master.
S =Slave.
M
S
Access door panel
Access door panel
Summary of Contents for 50124319