LOCK RELEASE INSTALLATION
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole. In case of wood door,
use a
Ø3mm. drill.
IMPORTANT:
the lock release to be used must be of 12Vd.c.
If you are using a.c. lock releases, use a SAR-12/24 relay unit and
a TF-104 transformer to activate it, as it is shown on page 155.
POWER SUPPLY INSTALLATION
ock release installation.
L
129
DOOR PANEL PROGRAMMING
For fast searching press one of the arrow keys followed by the number of entries to be
skipped. For a faster search use arrow keys followed by number 0 (10 in 10 entries)
or key symbol (100 in 100 entries).
The search is realized of 5 in 5 entries. From that moment, each time
an arrow key is pressed the repertory advances 5 in 5 entries.
5
ext edit.
T
To introduce or edit text during programming, use the keypad as described. The maximum
number of characters in one text line is 16.
Use the numeric keys to introduce text: press several times the corresponding key till the
desired character appears on the display, according with the enclosed characters table.
O.K.
ANCEL
C
1
4
2
5
3
6
7
8
9
0
ast repertory search.
F
Use the arrow keys to move through the display.
Press to record the whole text. The display
will show the message
settings recorded
.
Press key to exit from edition. The former text will be restored
and the display will show the message
cancelled
.
Use the key symbol to delete the actual character. The rest of the text
will be moved one position backward.
nstalling the FA-PLUS and FA-PLUS/C power supplies.
I
DIN 46277
3,5 x 25
DIN-7971
3,5 x 25
DIN-7971
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the power supply by using a
thermo-magnetic circuit breaker. Use a ground
connection with FA-Plus power supply.
To install the power supply directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the transformer with the
specified screws.
The power supply can be installed on a DIN 46277
guide simply pressing it.
To disassemble the power supply from the DIN guide,
use a plain screwdriver to lever the flange as shown
on the picture.
The FA-Plus/C model uses 6 units over DIN guide and
10 units the FA-Plus model.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power supply is
10, and 50 units in case of a FA-Plus model. Link power supplies to connect more
units than the specified as it's shown on page 155.
Install the power supply in a dry and protected place without risk of drip or water projections.
To avoid an electrical shock, neither remove the primary protection cover nor handle the connected
wire in the terminals.
The installation and handling of these equipments must be performed by authorised personnel and
without the power connected.
To avoid damage, the power supply has to be firmly fixed.
M 4 x 8
3,5 x 25
DIN-7972
DIN-963