6.0
GOTIS electrical adjustment values
Electrical check
left-hand
side of vehicle
NOMINAL values
right-hand
side of vehicle
NOMINAL values
5.1.1
Electrical check of
voltage supply at
measuring amplifier
23 + 8 V
23 + 8 V
5.1.2
Electrical check of
voltage supply at
measuring cell
5 ± 0.2 V
5 ± 0.2 V
5.1.3
Electrical check of
measurement signal
0.0 ± 1.0 mV
0.0 ± 1.0 mV
5.1.4
Electrical check of output
signal at measuring
amplifier
4 ± 0.5 mA
4 ± 0.5 mA
If the ACTUAL values deviate from the NOMINAL values please
consult the trouble-shooting list in section 7.0.