5.1.3
Checking the measuring signal
This check is to check the signal voltage at the measuring cell. Lifting
mechanism lifted without load.
Description of the
check
Value
left side of vehicle
Terminal 9 + 10
Value
right side of vehicle
Terminal 19 + 20
Checking operating
voltage at measuring
amplifier between the
terminals.
Observe the polarity:
Red measuring tip to
terminal 9/19 = “-” or
“white”
Black measuring tip to
terminal 10/20 = “+” or
“green”.
See section 6 for the nominal values for the electrical check.
If the values are exceeded replace the measuring cell and measuring
amplifier.
rsi / 03.2009
Goldhofer Aktiengesellschaft ··· Donaustrasse 95 ··· D - 87700 Memmingen
WA part 1/0
GOTIS AST-2 R
Phone +49 (0)8331/15-0 ··· FAX +49 (0)8331/15-239
GOTIS_AST-2-R_eng_00.vp
GOTIS maintenance
Chapter 5
Maintenance tasks
Page 5
Fig. 3
Checking the measuring signal