Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 47
gmpopcorn.com
32 oz. Unit - Oil Volume
Large Load: default is 11 oz. oil (adj. range 1-23 oz.)
Small Load: default is 6 oz. oil (adj. range 1-18 oz.)
3.
Press ENTER to accept the change
(press X to
exit screen and leave value unchanged).
If a volume outside the adjustment range
is entered,
the value remains unchanged.
To Change LOAD Temperature:
1.
Select a Load Temp to adjust
(pop-up window shows current setting).
2.
Enter the new temperature, or press
▲ or ▼ to
adjust amount in 1 degree increments.
For ALL Kettle Sizes
Butterfly Corn: default temp is 420°F (215°C);
[adj. range 390-450°F (199-232°C)]
Mushroom Corn: default temp is 440°F (227°C);
[adj. range 390-450°F (199-232°C)]
3.
Press ENTER to accept the change
(press X to
exit screen and leave value unchanged).
Load Temp ERROR - Auto-Corrections:
•
If a temperature outside the adjustment range is entered, the value remains unchanged.
•
The load temperature CANNOT be lower than the dump temperature.
(Attempting to
move the load temperature
below
the dump temperature will result in the dump temperature
automatically adjusting to correct the error.)
To Change DUMP Temperature:
1.
Select a Dump Temp to adjust.
(pop up window shows current setting)
2.
Enter the new temperature, or press
▲ or ▼ to
adjust the amount in 1 degree increments.
For ALL Kettle Sizes
Butterfly Corn: default temp is 410°F (210°C);
[adj. range 380-440°F (193-227°C)]
Mushroom Corn: default temp is 420°F (215°C);
[adj. range 380-440°F (193-227°C)]
3.
Press ENTER to accept the change
(press X to
exit screen and leave value unchanged).
Dump Temp ERROR - Auto-Corrections:
•
If a temperature outside the adjustment range is entered, the value remains unchanged.
•
The dump temperature CANNOT be higher than the load temperature.
(Attempting to
move the dump temperature
above
the load temperature will result in the load temperature
automatically adjusting to correct the error.)