Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 17
gmpopcorn.com
Nozzle and Fusible Link Locations
Each Updraft and Downdraft PopClean Popper is equipped with spray nozzles and temperature
rated fusible links located throughout the Fire Suppression System. This section describes the
nozzle and link types and locations on Updraft and Downdraft Models.
280°F Fusible Link
High temperature rated link
for first response to a kettle
fire (one for each kettle).
Fire Damper
In the event of a fire in the blower compartment,
the Fire Damper will close to prevent flames
from escaping the unit.
Updraft Models
–
Spray Nozzle and Fusible Link Locations
Updraft units have 2 Fusible Links (3 Fusible Links on Twin Models) and 5 Spray Nozzles (9 Spray
Nozzles on Twin Models).
2W Spray Nozzle
(two nozzles used
for each kettle)
2W Spray Nozzle
2W Spray
Nozzle
Link
1
Link
2
280°F Fusible Link
High temperature rated
link (located in cabinet
base) for oil supply fire
detection. To access,
remove oil dispense unit.
1N Spray Nozzle