0020167175_01 - 02/13 - Glow-worm
18.7.2
2A Fuse Rating
•
For access, refer to chapter "Main PCB".
•
The fuse is located at top right hand side of the PCB, see
chapter "Electrical connection
>
Wiring diagram".
18.7.3
User interface PCB
A
C
B
B
5
4
3
2
1
Key
1 User
interface
2 Retaining
slots
3 User interface PCB
4 Retainings
clips
5 Control
Panel
•
Remove the user interface (1) easing back the two retaining
slots (2).
•
Ease back the two PCB retaining clips (4) and withdraw the
PCB from the retaining lugs.
•
Remove the electrical connections to the PCB.
•
When re
fi
tting the user interface, ensure the leads are not
trapped.
18.7.4
Mains supply cable
e
DANGER:
The main supply cable must be replaced by a quali
fi
ed
and competent electrician.
•
If the main supply cable is damaged, replace it refering to the
chapter "Electrical connection".
19 Spare parts
In order to guarantee the safe and prolonged life of the product,
manufacturers genuine spare parts must be used.
i
IMPORTANT:
This appliance displays a CE Mark of conformity. Only
use the manufacturer’s genuine, new spare parts.
•
Ensure that spare parts are correctly mounted in the right
position and direction. After
fi
tting any spare part or servicing,
the appliance must be tested for its safe operation.