0020167175_01 - 02/13 - Glow-worm
9 Evacuation of combustion gas
9.1 Regulation
b
ATTENTION:
Only
fl
ue accessories supplied by Glow-worm must be
used.
Di
ff
erent
fl
ue outlet con
fi
gurations can be carried out.
•
Consult your supplier for more information about the other
possibilities and associated accessories.
44 mm/m
1
2
3
4
•
Standard
fl
ue terminal kits have an in-built fall back to the
boiler to drain the condensate. These can be
fi
tted level
between the appliance and the termination position. All other
extended
fl
ues must have a fall of at least 44mm/m
The maximum length of the
fl
ue outlet is de
fi
ned according to its
type (for example C13).
•
Whatever the kind of
fl
ue system chosen, observe the
minimum distances indicated in the chart below to position
the
fl
ue terminals.
•
To install the
fl
ue, refer to the separate
fl
ue instruction
supplied with your appliance.
•
Explain these requirements to the user of the appliance.
a
DANGER:
If necessary, you must install a
fl
ue terminal guard.
b
ATTENTION:
Caution! The connection between the
fl
ue elbow and the
fl
ue outlet must be sealed.
In GB the minimum acceptable siting dimensions for the terminal
from obstructions, other terminals and ventilation openings are
shown in diagram overleaf.
In IE the minimum distances for
fl
ue terminal positioning must be
those detailed in I.S.813 “Domestic Gas Installations”.
The terminal must be exposed to the external air, allowing free
passage of air across it at all times.
Being a condensing boiler some pluming may occur from the
fl
ue
outlet. This should be taken into consideration when selecting
the position for the terminal.
Carports or similar extensions of a roof only, or a roof and one
wall, require special consideration with respect to any openings,
doors, vents or windows under the roof. Care is required to
protect the roof if made of plastic sheeting. A carport is de
fi
ned
as a roof and one wall.
b
ATTENTION:
If the
fl
ue terminal is positioned near a light source
insects may enter the
fl
ue system. Where safe and
practical to do so advise the homeowner to check the
fl
ue outlet and clear visible insects from the terminal
end.
Position Position of the
fl
ue terminal
mm
Horizontal
fl
ues
A
directly below an opening, air brick,
opening windows
300
B
above an opening, air brick, opening windows
300
C
horizontally to an opening, air brick, opening
windows
300
D
below gutter, drain/soil pipe
25
E
below eaves
25
F
below a balcony or car port
25
G
from vertical drain pipes and soil pipes
25
H
from internal/external corners
25
H*
to a boundary alongside the terminal
300
I
above adjacent ground or balcony level
300
J*
from surface or a boundary facing the terminal
600
L
from opening (door/window) in car port
into dwelling
1200
M
vertical from a terminal
1500
N
horizontally from a terminal
300
Vertical
fl
ues
P
from another terminal
600
Q
above roof level
300
R
from adjacent opening window
1000
S
from adjacent wall to
fl
ue
300
(*) These dimensions comply with the building regulations,
but they may need to be increased to avoid wall staining and
nuisance from pluming depending on site conditions.
INSTALLATION
- 15 -