0020167175_01 - 02/13 - Glow-worm
7.4 Mounting
•
Make sure that the equipment used for implementing the
installation is compatible with that of the appliance.
•
Determine the assembly location. See the "Appliance location"
chapter.
117
892
* 80/125
fl
ue = Ø150mm
** 80/125
fl
ue = Ø130mm
*** 80/125
fl
ue = 156mm
•
Take the wall template and place in the desired position
on the wall, giving due consideration to the required boiler
clearances, see chapter "Appliance location > Clearances", and
the
fl
ue you are
fi
tting.
7.4.1
Fixing to the wall
130
90°
4
5
6
2
1
3
Key
1 Wall
template
2 Standard
fl
ue length horizontal
3 2.5° 44mm/metre inclined extended
fl
ue length
4 Wall
plug
5 Hanging
bracket
6 Screw
Flue hole cutting
•
Mark the position of the
fl
ue centre.
•
Remove the wall template, then drilling the
fl
ue hole.
i
IMPORTANT:
The
fl
ue is designed with an internal fall of 44mm/metre
(2.5
o
), therefore the hole can be drilled horizontally.
•
Use a 105mm diameter core drill for external access
fl
ue
installation (60/100
fl
ue) (80/125
fl
ue > Ø130mm).
•
Use a 125mm diameter core drill for internal access only
fl
ue
installation (60/100
fl
ue) (80/125
fl
ue > Ø150mm).
i
IMPORTANT:
If
fl
ue extension pipes are to be used then a core drill
size of 125mm is required. This will allow the extension
pieces to slope at 44mm/metre (2.5
o
) towards the boiler.
•
If
fi
tting a side
fl
ue, extend the
fl
ue centre line into the corner
then 130mm along the adjacent wall.
•
If
fi
tting an extended side
fl
ue, determine the
fl
ue hole centre
by extending the dashed inclined line on the template to the
side wall. This dashed line is drawn at 44mm/metre (2.5o)
rise from the boiler. Where this line reaches the side wall, a
horizontal line should be marked. The vertical centre line of
the
fl
ue should then be marked at 130mm from the back wall.
To allow for the
fl
ue passing through the wall at this angle
a 125mm hole should be drilled irrespective of internal or
external installation.
Hanging bracket
fi
Due to the varied site conditions the
fi
xings supplied may not be
suitable, please make sure that those used are.
•
Drill the holes for the
fi
xing screws in accordance with the wall
template.
•
Fix the hanging bracket on the wall.