9
221473B
2 Boiler Position
2.1 Location
The boiler must be installed in accordance with the rules in
force in the countries of destination.
The boiler is not suitable for fitting out of doors.
Any electrical switch or boiler control using mains electricity
must be positioned so that it cannot be touched by a person
using the bath or shower.
The boiler must be mounted on a flat wall which is sufficiently
robust to take its weight, refer to Section 1 ‘Data’.
If the location of the boiler or any part of the system is subject
to severe cold weather conditions, it is recommended that a
frost thermostat is fitted. Any part of the system that may be
vulnerable to freezing must be protected.
If the boiler is to be fitted into a cupboard, compartment or
unusual location, special procedures are necessary.
Make sure that the cupboard or compartment air vents are
positioned to be clear of obstructions at all times, refer to
Section 3.
2.2 Clearances
The boiler should be positioned so that at least the minimum
operational and servicing clearances are provided, see diagram
5 Instructions for Use.
Additional clearances may be required around the boiler for
installation.
For flue installations where external access is not practicable,
the clearances around the boiler may need to be increased as
follows.
For rear flue installations the dimension between the boiler
mounting wall and a permanent facing wall must be a minimum
of “X”, see diagram 3.1 and 3.3, plus 272mm.
For side flue installation the dimension between any adjacent
permanent walls must be a minimum of “Y”, see diagram 3.2
and 3.4, plus 332mm.