Supplied By www.heating spares.co Tel. 0161 620 6677
6
221473B
5
5
150
5
5
150
5
*
*
*
*
Increase to 25mm clearance from
combustible material.
Dimensions in millimetres
800
Diagram 4
WATER VALVES
SLOT(OPEN)
DRAIN
POINT
COLD WATER
SUPPLY IN
HEATING
FLOW
GAS
SERVICE
COCK
HEATING
RETURN
2793
HOT
WATER
OUT
SAFETY
VALVE
DISCHARGE
SLOT(OPEN)
Diagram 3
6622
Orange Light 'MAINS'
Green Light 'RUNNING'
Red Light 'LOW C.H. WATER
PRESSURE'
5044
SWITCH
'ON'
CONTROL
RESET
BUTTON
SWITCH
'OFF'
PRESSURE GAUGE
‘A’
CENTRAL HEATING
SELECTOR SWITCH
'C'
Protection Against Freezing
If the boiler is to be out of use for any long periods during severe
weather, it is recommended that the whole system, including
the combination boiler, should be drained to avoid the risk of
freezing.
If in doubt, contact you installation/servicing company for advice.
Draining and Filling
CAUTION. This boiler works in a pressurised system which
must only be drained, refilled and pressurised by a competent
person.
Note: If the pressure gauge indicates a loss of system pressure,
that is, less than 0.7bar, YOU MUST CONTACT YOUR
INSTALLER.
Pressure Relief Safety Valve
CAUTION. A pressure relief safety valve and discharge pipe is
fitted to the boiler. This valve must not be touched. Should there
be any discharge from the pipe, turn the boiler off, isolate from
the electrical supply and contact your installation/servicing
company.
Cleaning
WARNING. This appliance contains metal parts (components)
and care should be taken when handling and cleaning with
particular regard to edges.
The boiler casing can be cleaned using a mild liquid detergent
with a damp cloth, then a dry cloth to polish.
Do not use any form of abrasive or solvent cleaner as you may
damage the paint work
Boiler Casing
CAUTION. Do not remove or adjust the casing in any way, as
incorrect fitting may result in incorrect operation or failure to
operate at all. If in doubt seek advice from the local gas
company or your installation/ servicing company.
Replacement Parts
If replacement parts are required apply to your local supplier or
British Gas.
Please quote the name of the appliance.
Diagram 5
2811
Instructions for Use