1 General Data
Diagram 1.1
5275
2804
ALL DIMENSIONS in MILLIMETRES
KEY:
22mm COMPRESSION
CENTRAL HEATING
15mm COMPRESSION
DOMESTIC WATER
Rc
1/
2
(
1/
2
in. BSPT)
GAS CONNECTION
63
331
168
133
450
63
SAFETY
VALVE
DISCHARGE
783
25
2.5
66
66
107
107
101
WATER
THROTTLE
MINI
EXPANSION
VESSEL
HEAT EXCHANGER
MAIN BURNER
PRESSURE
SWITCH
D.H.W.
COLD
INLET
C.H.
FLOW
SAFETY
VALVE DISCHARGE
PUMP
SPARK
ELECTRODE
AUTOMATIC
AIR VENT
FANNED
FLUE
EXPANSION
VESSEL
FLOW
SWITCH
SAFETY
VALVE
GAS VALVE
D.H.W.
HOT
OUTLET
C.H.
RETURN
GAS
SUPPLY
1.1 Installation
Materials and equipment should be fit for their purpose and of
suitable quality and workmanship.
1.2 Important Notice
This boiler is for use only on natural gas, G20.
1.3 Sheet metal Parts
WARNING. When installing the appliance, care should be
taken to avoid any possibility of personal injury when handling
sheet metal parts.
1.4 Requirements
The installation of this boiler must be carried out by a competent
person in accordance the rules in force in the countries of
destination.
Manufacturer’s instructions, supplied.
Manufacturer’s instructions must not be taken as overriding
statutory requirements.