3 Fault Finding
Diagram 3.4
5084
Carry out initial Fault Finding checks described in Section 3.1 and 3.4. Check that gas, water and electricity
are available at the boiler.
Before starting the test, isolate the boiler from the electrical supply, ensure that the remote
controls are not calling for duty. Refer to the functional flow diagrams in conjuction with the
following fault finding.
Remove outer case control housing, control housing cover, user control knob and the cover.
Check all connections on the controls boards. Rectify or renew as necessary.
Restore power to the appliance.
Is the Orange 'Mains' light illuminated?
Refer to Electrical Control Fault Finding
Faulty 'User Control' Replace
Does Pump run?
Turn on hot water tap.
Is the Green 'Running' light illuminated?
Faulty 'User Control' Replace
With central heating demand on.
Can the temperature be varied by rotating the
control knob?
Turn off C.H. and D.H.W demand.
Simulate a leak on Central Heating Circuit by
draining the appliance. As pressure approaches
'ZERO' does the Red 'Low Pressure' light flash?
User Control board in order
To stop Red 'Low Pressure' light flashing.
Refill C.H circuit to 0.7 bar then switch the
electrical supply to the appliance off and then on.
Proceed to Electrical Controls fault finding
if fault persists.
See Electrical Controls fault finding for
'Water Pressure Switch', if in order
replace faulty user control
Faulty 'User Control Replace
START
YES
NO
YES
NO
YES
NO
YES
NO
NO
YES
Carry out initial Fault Finding checks described in Section 3.1 and 3.4. Check that gas, water and electricity
are available at the boiler.
Before starting the test, isolate the boiler from the electrical supply, make sure that the remote
controls are not calling for duty. Refer to the functional flow diagrams in conjunction with the
following fault finding.