Page 6
Installation
UNPACKING
Unpack the mixer immediately after receipt. If the machine is found to be damaged, save the packaging material
and contact the carrier within fifteen (15) days of delivery. Immediately contact your source of the equipment.
You have no recourse for damage after fifteen (15) days.
TO AVOID SERIOUS PERSONAL INJURY:
•
ALWAYS
install equipment in work area with adequate light and space.
•
ONLY
operate the mixer on a solid,
LEVEL
, non-skid surface that is nonflammable.
•
NEVER
bypass, alter, or modify this equipment in any way from its original condition. Doing so may create
hazards and will void the warranty.
•
NEVER
operate the mixer without all warnings attached to it.
•
DO NOT
attempt to lift the mixer alone.
INSTALLATION
1. Read this manual thoroughly before installation and operation. DO NOT proceed with installation and
operation if you have any questions or do not understand anything in this manual. Contact your local
representative or Globe first.
2. Remove the corrugated box from the skid by removing the bands on the box. NOTE: The SP62P and SP80PL
are shipped in a wooden crate; only the bolts at the bottom of the crate (all four sides) need to be removed.
3. Carefully unbolt the mixer from the skid using an 11/16'' or 3/4'' wrench.
4. Select a location for the mixer keeping these points in mind:
• Floor or counter must be level.
• Easy access for maintenance and service.
• Clearance for operating controls, installing and removing agitators, bowl, or attachments.
• Sufficient space for adding ingredients during mixing periods.
• Ensure rear ventilation outlet of mixer is not blocked.
5. Use at least two other people to tilt the unit and install the rubber feet.
6. A bolt down template and bolts are available for the SP10, SP20, or SP25. Contact Globe if needed.
7. Inspect the mixer to ensure all parts have been provided (i.e. bowl, beater, whip, and dough hook). The SP62P
only has a bowl, dough hook, and bowl truck.
8. Read the electrical information found on the data plate located at the rear of the machine. The incoming
power should match the rating on the data plate.
CONNECTING TO ELECTRICAL POWER
Cord Connected Units: This machine is provided with a three-prong grounding plug. The outlet that
this plug is connected to must be properly grounded. If the receptacle is not the proper grounding type,
contact an electrician. Do not under any circumstances cut or remove the third ground prong from the
power cord or use any adapter plug. Never use an extension cord. Low power supply could damage the
mixer or cause a fire.
Summary of Contents for SP10
Page 2: ......