TROUBLESHOOTING GUIDE
TROUBLE
POSSIBLE CAUSE
PROCEDURE
REMEDY
Accepted Coins Always
Front Cover
Check front cover for proper
Clean or replace front cover.
Go to Cashbox
installation, check the mirrors
Acceptor
If coin still goes to cashbox, replace
Reprogram acceptor coin
acceptor with good acceptor and test
routing.
to see if changer functions properly.
If coin still goes to cashbox,Replace acceptor.
Tube Sensor Board
Check the sensor board for loose
Replace tube sensor board.
components. Make sure tube
sensor board is properly secured
to main logic board. Check cable from
sensor board for damage or
improper connection.
If coin still goes to cashbox,Replace changers main
logic board
Accepted Coins Always
Coin tube gate is in
Remove acceptor back cover
Replace acceptor.
Go To Coin Tubes
the open position
and check solenoid for free
operation.
Tube Sensor Board
Replace tube sensor board with
Replace tube sensor board.
good board and test to see if
changer functions properly.
If coins still go to tubes,Replace changers main
logic board.
Changer Credits Coins
Coin return lever
Make sure changer is mounted
Reposition changer and/or
But Does Not Escrow
correctly and acceptor gate opens
vendor coin return lever.
when vendor coin return lever is
operated.
Acceptor
Replace acceptor with good
Replace defective acceptor.
acceptor and test to see if
changer operates correctly.
SINGLE PRICE ONLY
Uninhibit the escrow feature.
Turn Switch 9 OFF and press
Switch 9 is ON-escrow
the Mode Switch.
is inhibited
No Payout
Payout Motor
Make sure motor wires are
Plug motor wires into
properly connected to changers
main logic board.
main logic board.
If still no payout, replace motor
Replace defective
with good motor and test to see if
payout motor.
changer operates properly.
Make sure coin is routed to that tube.
SECTION 5: TROUBLESHOOTING