background image

 www.vega-absolute.ru 

 

 

 

 

 

NB-IOT PULSE COUNTER 

VEGA NB-11 

USER MANUAL 

 

 

 

 

 

 

 

 

DOCUMENT REVISION 

FIRMWARE VERSION 

06 

1.3 

 

 

 

 

 

Summary of Contents for VEGA NB-11

Page 1: ...www vega absolute ru NB IOT PULSE COUNTER VEGA NB 11 USER MANUAL DOCUMENT REVISION FIRMWARE VERSION 06 1 3...

Page 2: ...gorithm 4 Functional 5 Marking 5 2 SPECIFICATION 6 Device Specification 6 Default Device Settings 7 3 OPERATION 8 Device Appearance 8 Contacts 10 Pulse Inputs Settings 11 Hall Sensor 12 Buttons 13 Ind...

Page 3: ...mation on powering and activation procedure control commands and functions of the counter This manual is targeted at specialists familiar with installation work fundamentals of electronic and electric...

Page 4: ...s stored in the device memory and transmitting during the next communication session with the NB IoT network Data are transferred with a configurable schedule too Data can be transferred in random poi...

Page 5: ...s etc Queue of sending when delivery is not possible Time referencing of readings by internal clock Communication in case of security inputs or Hall sensor actuation Temperature measurement Charge mea...

Page 6: ...ature sensor yes Hall sensor yes Quantity of black box records up to 100 000 CELLULAR COMMUNICATIONS Supported Cellular Standards LTE Cat NB1 Data transfer protocol MQTT Calculated number of transmitt...

Page 7: ...ata collection period 24 hours Time zone UTC 00 00 Guard inputs operate on short Hall sensor ON Send network statistics OFF Pulse filtering settings 50 ms for pulse and pause For changing the device s...

Page 8: ...rail The device case is equipped with a hermetic gland of M12 size A sealant is installed inside the gland ensuring compliance with the declared Ingress Protection rating of the device case 2 cable g...

Page 9: ...ements for manage and indication as well as connecting contacts are placed on the board inside the case 4 input for connecting an external antenna 5 contacts 6 USB port 7 LED indicators 8 SIM holder 9...

Page 10: ...equencies up to 200 Hz The pulse counter allows to connect circuits with the following types of NO contacts reed switch mechanical pushbutton open collector output Equipment with NAMUR pulse output is...

Page 11: ...of falling and rising there are many additional impulses that need to be no considered in the calculation In addition the pulse duration floats and depends on the current flow rate of the meter For c...

Page 12: ...2 January 2022 HALL SENSOR The device has Hall sensor which located on the board edge on the bottom side When the magnet is brought up the sensor triggered and the device can form the alarm message wh...

Page 13: ...econd Registration at the network Pressing for 2 seconds Data transmitting Pressing for 3 seconds LTE modem switching off Pressing for 4 seconds To form record to the black box When you hold down the...

Page 14: ...Device searches the network Short flash every second Device is successfully registered and it is in the network Two short flashes every one second Device transmits data to the network No light LTE mod...

Page 15: ...act GND Before starting mounting work you must make sure that the latest firmware version is installed on the equipment For mounting you will need SIM card wire stripper laptop Step by step mounting b...

Page 16: ...ep until the next communication session 7 If you need to test the data transmitting then press and hold the INIT button for the 2 seconds 8 Before assembling the device you can reset the pulses accumu...

Page 17: ...ished and a client name the name which the device use for publishing All those settings specified in Vega NB IoT Configurator in part MQTT settings For watching the data sending by the device you shou...

Page 18: ...e pulse1 pulse number on the input 1 pulse2 pulse number on the input 2 pulse3 pulse number on the input 3 pulse4 pulse number on the input 4 s_alarm1 state of ALARM1 input at the time of data slice 0...

Page 19: ...TION REQUIREMENTS Vega NB 11 pulse counter shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The counter shall be transported in cover...

Page 20: ...11 User Manual 20 Revision 06 of 12 January 2022 6 CONTENT OF THE PACKAGE The pulse counter is delivered complete with Vega NB 11 pulse counter 1 pc Antenna 1 pc Battery 6400 mAh 1 pc Factory certific...

Page 21: ...he factory certificate does not have an TCD stamp and or there is no sticker with information about the device the serial number DevEUI EMEI printed on the product differs from the serial number DevEU...

Page 22: ...n Date Name Comments 01 17 06 2019 KEV The first release 02 14 07 2020 KEV Minor changes 03 08 10 2020 KEV We recalculate the number of transmitted packets in warranty conditions 04 02 03 2021 KEV New...

Page 23: ...Vega NB 11 User Manual 23 Revision 06 of 12 January 2022 vega absolute ru User Manual Vega Absolute OOO 2019 2022...