background image

                                                                                                                         

Model

R313FB 

 

 

 

 

Wireless Activity Event Counter

 

 

 

 

 

Wireless Activity Event Counter 

 

 

R313FB 

User Manual   

 

 

 

 

 

Copyright©Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX 

Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole 

or in part, without written permission of NETVOX Technology. The specifications are subject to change 

without prior notice. 

Summary of Contents for R313FB

Page 1: ...Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in wh...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 11 7 Relative Devices 12 8 Important Maintenance Instruction 12...

Page 3: ...ong distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long dista...

Page 4: ...be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery Life Ple...

Page 5: ...ter engineer testing mode Network Joining Never joined the network Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off f...

Page 6: ...ure is 9 8 m s2 The scale factor of the threshold is 62 5 mg R313FB vibration alarm When the device detects a sudden movement or vibration change of the quiescent state the device waits for DeactiveTi...

Page 7: ...erval Unit second Max Interval Unit second Reportable Change Current Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report...

Page 8: ...ID DeviceT ype NetvoxPayLoadData SetR313F TypeReq R313FB 0x03 0x50 R313FType 1Byte 0x01_R313FA 0x02_R313 FB 0x03_R313FC Reserved 8Bytes Fixed 0x00 SetR313F TypeRsp 0x83 Status 0x00_success Reserved 8B...

Page 9: ...turns 8650000A06000000000000 current device type R313FB Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTi...

Page 10: ...2 8V Does not report Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORT 2 8V Wakes up and collects data 2 7V 2 7 2 8 0 1 REPORTS 2 7V Wakes up and collects data 2 7V Doe...

Page 11: ...rts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval va...

Page 12: ...a sudden movement or vibration and it will immediately sends a report After the vibration alarm the device waits for a certain period of time DeactiveTime default 5 seconds can be modified to enter th...

Page 13: ...hen the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit b...

Reviews: