background image

    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

iCASH 15 Cleaning Instruction 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Edition November 2010 

 

 

Summary of Contents for iCASH 15

Page 1: ...iCASH 15 Cleaning Instruction Edition November 2010 ...

Page 2: ...ternational GmbH 2010 All rights including the rights to the translation reprinting transmission or copying by any means in whole or in part are reserved Offenders will be liable for damages All rights including rights resulting from a patent grant or registration of a utility or design are reserved ...

Page 3: ...ng interval as needed Cleaning material Wet cleaning cloths for stainless steel surfaces Ballistol oil for cleaning stainless steel for varnished surfaces Wincor Nixdorf cleaning set for plastic surfaces Wincor Nixdorf cleaning set Cleaning the coin paths The conveyer belts must not come into contact with alcohol Clean the coin paths with compressed air Cleaning interval when necessary at least on...

Page 4: ...iCash 15 Cleaning Instruction 2 Coin Validator User and Service Staff Unlock the iCASH 15 1 and pull out the unit 2 Swing the front cover open 1 2 1 2 2 ...

Page 5: ...hard toothbrush to clean the device Finally clean the area with a slightly moistened Isopropylalkohol cloth and then dry it To clean the whole area shaded area turn the green wheel 1 to bring the rotor 2 to a different position Pay special attention to the thickly white marked area 3 Mount the device in logically reverse order 2 3 1 ...

Page 6: ...site and cover the light barriers with your cleaning cloth to start running the conveyer belt Clean the running conveyer belt with a wet cloth The liquid must not contain alcohol Never use spray Clean the light barrier sensors from dirt and dust with compressed air Find 6 holes sensors inside 3 on each side see arrows Conveyer belt ...

Page 7: ...iCASH 15 Cleaning Instruction 5 Coin Conveyer Sensors Service Staff only Unlock the iCASH 15 1 and pull out the unit 2 Swing the front cover open 1 1 1 2 2 ...

Page 8: ...over to the right While holding the cover open press the coin conveyer unit lockings carefully to the right and to the left see arrows and open the device i Never use a knife a scissor or any other sharp objects to clean the device Press here to the left Press here to the right ...

Page 9: ...barrier sensors using a cotton bud moistened with Isopropylalcohol The conveyer belts must not come into contact with alcoholic solutions After cleaning close the coin conveyer belt housing and the coin validator with the green lever Close the device ...

Page 10: ...iCash 15 Cleaning Instruction 8 Hopper Sensor Service Staff only Unlock the iCASH 15 1 and pull out the unit 2 Swing the front cover open 1 1 1 2 2 ...

Page 11: ...ASH 15 Cleaning Instruction 9 Unlock the unit 1 and swing it upwards to the stop 2 Remove all hoppers to clean the sensor 1 with a cloth moistened with Isopropylalcohol Set the hoppers back in place 1 2 1 ...

Page 12: ...iCash 15 Cleaning Instruction 10 Push the green lever and close the unit ...

Page 13: ...es keyboards and housing Not suitable for cleaning conveyer belts Dry cleaning cloths Antistatic and fluff free Pack with 300 cloths 01750097334 For cleaning display panes Compressed air spray PRESSAIR 400ml bottle without a valve 70cm hose 01750097331 Cleaned compressed air FCKW free for removing loose dust and dirt particles Cloth with ISOPROPYL 1000 pieces 01750104065 Pure isopropyl alcohol for...

Page 14: ...Wincor Nixdorf International GmbH D 33094 Paderborn Order No 01750206779A ...

Reviews: