Chapter 4 — Operator Menu and Game Setup
©2006 Global VR, Inc.
040-0120-01 Rev. B 10/10/2006
Page 13 of 56
Using the Gun Test & Calibrate Screens
1.
Select
GUN TEST & CALIBRATE
from the System Tests menu. The screen shown below on
the left will open. Observe the lists on the left and right side of the screen. Each of these
provides information about the gun on that side of the cabinet.
2.
Move a gun and observe the corresponding icon moving on the screen. When the gun is properly
calibrated, you should be able to move the icon all around the edge of the screen, without going
off the screen. Note that the coordinate numbers next to X and Y on the screen change as you
move the gun.
3.
Press the Trigger, Flamethrower, and Grenade buttons and observe that the corresponding word
changes color onscreen. You should also feel the
Kicker
(force-feedback recoil) when you pull
the trigger.
4.
To test the gun LED display, press the Grenade button to cycle the ones-place LED, and press
the Flamethrower button to cycle the tens-place LED. Confirm all LED segments light, and the
readout matches the onscreen number next to LED for that gun.
5.
To calibrate the right gun (Player 2), press the START button for that gun.
6.
The Gun Calibration screen, shown below on the right, will appear. When the screen first
appears, only the PLAYER 2 GUN LEFT numbers will be visible, and a blue triangle will be
visible at the far left of the screen, as shown below.
As you move the gun, the numbers next to PLAYER 2 GUN LEFT will change, indicating
the gun position. Point the gun at the far left of the screen, as indicated by the triangle, and
pull the trigger to set the position.
7.
Once you set the LEFT position, PLAYER 2 GUN RIGHT will automatically become active,
and a blue triangle will appear at the far right of the screen. Move the gun all the way to the
right and pull the trigger.
8.
Set the UP and DOWN positions the same way. Once you set the DOWN position, the screen
shown below on the left will appear again.
9.
When finished testing guns, press the
SELECT
button to return to the System Tests Menu.
Figure 8.
Gun Calibration Screens
Summary of Contents for Aliens Extermination
Page 55: ......