Chapter 6 — Service and Repair
Aliens Extermination System Manual
Page 34 of 56
040-0120-01 Rev. B 10/10/2006
Coin Mech Replacement
Perform the following steps to remove the coin mech. You can replace the coin mech with any
standard arcade coin mech.
1.
Unscrew the thumbscrews on the latches as shown by the arrows in step 1 of the figure below.
2.
Slide the latches apart from each other and remove the Coin Mech as shown in steps 2 and 3.
3.
Reverse these steps to re-install a coin mech. It is important to verify the operation of the newly
installed coin mech with both good and bad coins.
Figure 29.
Servicing the Coin Mech and Coin Meter
Coin Meter Replacement
The coin meter is located in the bottom left-hand corner of the coin vault. It receives power via
the GVRI/O PCB. If the coin meter stops working, first check the 5A fuse on the GVRI/O PCB
and replace it if blown. Perform the following steps to replace the coin meter:
1.
Turn the cabinet OFF and disconnect the AC power cord.
2.
Remove the two Phillips screws securing the coin meter to the cabinet and remove the coin
meter.
3.
Cut the two wires from the coin meter and strip the ends of the wires to attach the new meter.
4.
Use two butt splices to connect the wires to the new coin meter.
5.
Secure the new coin meter with the two screws removed previously.
Power Distribution Service
AC Power Plate
The AC power plate provides the external AC power connection. An AC EMI Filter in the
power plate removes electrical noise that can cause interference with the hardware inside the
cabinet.
AC power from the power plate is connected to a 7-outlet AC power strip/surge suppressor in the
cabinet.
Caution: The cabinet must be connected to a secure ground to function properly.