Chapter 9 — Diagrams and Schematics
Aliens Extermination System Manual
Page 52 of 56
040-0120-01 Rev. B 10/10/2006
To Ground Lug
Under Connector
L N
(AC)
-12V +24V +12V COM COM +5V
+5V ADJ.
Top View
AC Power Plate on Cabinet Rear (Top View)
White
Black
(Two middle terminals
are not used.)
DC Power Supply
Green
Set Input Voltage (110 or 220)
with switch on back.
To AC
Wall Outlet
To AC
Power Strip
Part#:
115-0049-01
L
N
AC Power Strip
Note:
Connection order does not matter.
Computer
DC Power Supply
Monitor
Part #: 115-0008-01
Marquee Light Fixture 1
Dollar Bill Validator (Optional)
Power On LED
Adjustment Pot
(Affects all Voltages)
White
Green
To Kickplate Lights
To Instruction Panel Lights
To Speaker Lights
To GVRI/O PCB
Black
GND
(Black)
Left Gun Power Connector
GND (Black)
+12V (Yellow)
Part #: 115-0098-01
+12V (Yellow)
+24V (White)
+12V (Yellow)
GND (Black)
Part #: 115-0101-01
To Cabinet Ventillation Fan
Chassis Ground Harness
Part#: 115-0101-01
To GVRI/O PCB
To Coin Vault Ground Lug
To Gun 1
To Gun 2
Right Gun Power Connector
GND (Black)
Part #: 115-0097-01*
+12V (Yellow)
+24V (White)
*Power Harness contains two fuses, one for each gun.
Ground Lug
Ground Lug
To Monitor Chassis
Figure 37.
Power Distribution Diagram
Summary of Contents for Aliens Extermination