4.4. Tuning & Offset
From the Tools menu drop down select the Control Panel dialog box. From the Setup
menu drop down select the Analog I/O dialog box. Arrange the boxes side by side.
Observe any small rotation in the Actual Velocity box in the control panel dialog.
Adjust that rotation to zero by changing the value in the Signal Offset box in
the Analog I/O dialog.
4.5. Saving your setup
You are almost done setting up. From the Setup menu drop down select Save
To NVM. When queried “Save card setup to Non Volatile RAM?” press the Yes
button. Setup is complete
4.6 Rigid Tap Test (Optional)
If desired you can test the rigid tap mode of your VMC by performing the following
procedure. This procedure is drawn from the FADAL maintenance manual.
Install test screw (SVT-0077). The screw can be fabricated from 1.000”
round stock, by threading a 14 TPI Acme thread.
Program is for Format 1. Use test program #6000 or the following program:
9
%
N1O6000(RIGID TAP CYCLE
N2G80
N3S750
N4G91
N5X0.1Y0.1G1F10.
N6M5
N7G4P2000
N8G84.1Z-1.R+0F500.Q0.0714
N9M45
N10X-0.1Y-0.1G1F10.
N11M45
N12M45
N13M45
N14M45
N15G80
N16G4P2000
N17M99P5
N18(!
N19( NOTE: O5827 CNC88 TEST WAS MOVED TO TA,5!!!
%
3801