4.3. Motor Parameters
From the Setup menu drop down, open the Induction Motor Vector Control dialog box
as seen below.
Motor Parameters Section;
In the working column enter the Stator Resistance (phase to phase) and
the Stator Inductance. The Nominal DC Bus and the Current Loop Bandwidth are
preset to 340VDC and 2000 Hz respectively and do not normally need to be changed.
Motor Safety Limits;
These parameters are preset at the factory and do not normally need to be changed
Vector Control Parameters;
In the working column enter the parameters listed.
Check that your parameters are correct and push the Send to Amp button,
The parameters in the working column will appear in the Amp column, next push
the Enable Amp button, then the Done button.
Close the box and from the Setup menu drop down select Save to NVM. Push the
Save button. This will save the parameters in the vector drive.