72
Troubleshooting
GBF-Series Fryers
7.01 Temperature Control System (continued)
Problem
Probable Cause
Repair Procedure
FRYER WILL NOT HEAT:
Power light
ON
.
Heat Switch in
HEAT
position.
High Limit light
ON
.
A. Power surge.
B. Sticking contactor.
C. Faulty High-Limit board.
D. Faulty High-Limit probe.
E. Line spikes or noise.
A. Turn Power Switch
OFF
for
approx. 5 seconds.
B. Replace contactor.
C. Replace High-Limit board.
D. Replace High-Limit probe.
E. Install Line Filter or remove
noise source.
7.02
Oil Filtration System
Probable Cause
Repair Procedure
OIL NOT RETURNING TO FRY
VAT
A. Pump Switch not in
PUMP
position.
A. Set Pump Switch to
PUMP
position.
B. Air leaks (hoses, fittings, filter
media).
B. Repair source of air leak.
C. Faulty pump motor.
C. Replace pump motor.
D. Oil pump clogged or jammed.
D. Free pump, clear obstruction.
E. Pump Diverter Valve not set to
OIL RETURN
position
E. Place Pump Diverter Valve in
OIL RETURN
position
F. Oil Return Valve set in
CLOSE
position
F. Place Oil Return Valve in
FILL
VAT
position
G. Pump had been used to pump
boil-out solution.
G. Disassemble, clean & re-oil
pump.
H. Old oil allowed to sit in pump
too long.
H. Run clean warm oil through
pump.
I. Oil too cool in Filter Pan.
I. Remove Filter Pan & manually
remove cool or cold oil.
J. Filter Pan assembled incorrectly. J. Assemble Filter Pan correctly.
K. Dirty Filter Pan.
K. Clean Filter Pan.
Problem
Summary of Contents for GBF-35 Banked
Page 4: ......
Page 12: ...x ...
Page 22: ...10 Installation GBF Series Fryers Notes ...
Page 32: ...20 Overview GBF Series Fryers 3 04 Lower Cabinet Area Add on Fryers for Banked Systems 1 2 ...
Page 42: ...30 Overview GBF Series Fryers Notes ...
Page 86: ...74 NOTES ...
Page 106: ...94 Parts List GBF Series Fryers 8 11 Filter Pan 3 1 5 4 2 8 9 7 10 6 A ...
Page 108: ...96 Parts List GBF Series Fryers Notes ...
Page 109: ...FOODSERVICE EQUIPMENT ...