GL-VP-150
User Manual
Copyright © 2009-2011 GigaLink
Page 27 of 37
payload, it
contains the following components:
GS_LOG: [device MAC address][error code] error message
Example
:
May
19
02:40:38
192.168.1.14
GS_LOG:
[00:0b:82:00:a1:be][000]
Ethernet link is up
Download
Device
Configuration
Used to download the change you have made.
Distinctive
Ring
Tone
Caller ID must be configured. Select a Distinctive Ring Tone 1
through 3 for a particular Caller ID. The GL-VP-150 will ONLY
use selected ring tones for particular Caller IDs. For all other
calls, the GL-VP-150 will use System Ring Tone. When
selected and no Caller ID is configured, the selected ring tone
will be used for all incoming calls.
System Ring Tone
System ring tone. Default is North American standard.
Adjust system ring tone frequencies and cadences based on
local telecom standard.
Call Progress Tones
Using these settings, users can configure ring or tone
frequencies based on parameters from local telecom. By
default, they are set to North American standard.
Frequencies should be configured with known values to avoid
uncomfortable high pitch sounds.
Syntax
: f1=val,f2=val[,c=on1/off1[-on2/off2[-on3/off3]]];
(Frequencies are in Hz and cadence on and off are in 10ms)
ON is the period of ringing (“On time” in „ms‟) while OFF is the
period of silence. In order to set a continuous ring, OFF should
be zero. Otherwise it will ring ON ms and a pause of OFF ms
and then repeat the pattern. Up to three cadences are
supported.
Restore
Configuration
User can restore the before configuration from the configuration
file saved at local pc