System Hardware Installation
Read the following guidelines before you begin to install the CPU:
• Make sure that the motherboard supports the CPU.
• Always turn off the computer and unplug the power cord from the power outlet before installing
the CPU to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
• Place the system unit on a flat and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to properly turn off the server before you start installing components may cause serious
damage. Do not attempt the procedures described in the following sections unless you are a
qualified service technician.
3-4 Installing the CPU and Heat Sink
Follow these instructions to install the CPU:
1. Align and install the processor on the carrier.
NOTE:
Apply thermal compound evenly on the top of the CPU. Remove the protective cover from
the underside of the heat sink.
2.
Carefully flip the heatsink. Then install the carrier assembly on the bottom of the heatsink and
make sure the gold arrow is located in the correct direction.
3. Remove the CPU cover.
NOTE:
Save and replace the CPU cover if the processor is removed from its socket.
4. Align the heatsink with the CPU socket by the guide pins and make sure the gold arrow is located in
the correct direction. Then place the heatsink onto the top of the CPU socket.
5. To secure the heatsink, tighten the screws in a sequential order (1
g
2
g
3
g
4).
NOTE:
When dissambling the heatsink, loosen the screws in reverse order (4
g
3
g
2
g
1).
1
2
3
4
1
4
3
2
• To install/remove the Intel heatsink use a T30-Lobe screwdriver or drill bit with a screw torque of
8.0 +/- 0.5kgf*cm (8lbf*in).
Summary of Contents for TO22-C20
Page 1: ...TO22 C20 High Performance Compute Server User Manual Rev 1 0 ...
Page 10: ... 10 This page intentionally left blank ...
Page 17: ... 17 System Appearance 2 3 Rear View 1 No Description 1 Bus bar connector assembly ...
Page 20: ...System Appearance 20 This page intentionally left blank ...
Page 26: ...System Hardware Installation 26 CPU0 Heatsink CPU1 Heatsink ...
Page 35: ... 35 System Hardware Installation HDD Back Plane Board Power Cable NVMe Cable ...
Page 36: ...System Hardware Installation 36 SL_CN2 U2_4 SL_CN3 U2_5 ...
Page 38: ...Motherboard Components 38 25 System battery 26 NVMe SSD connector 27 NVMe SSD connector ...
Page 40: ...Motherboard Components 40 This page intentionally left blank ...
Page 49: ...BIOS Setup 49 5 2 3 Intel R Ethernet Connection X550 ...
Page 58: ... 58 BIOS Setup 5 2 6 SIO Configuration ...
Page 72: ... 72 BIOS Setup 5 3 1 1 Pre Socket Configuration ...
Page 75: ...BIOS Setup 75 5 3 3 UPI Configuration ...