12. Use of SLOW RUN, SLOW STOP
12. Use of SLOW RUN, SLOW STOP
12. Use of SLOW RUN, SLOW STOP
12. Use of SLOW RUN, SLOW STOP
There arefunctions SLOW RUN that is accelerated gradually up to the speed of set and
SLOW STOP that is decelerated up to the speed of set in GSA TYPE.
Use these functions when want smooth acceleration and deceleration by relieve the shock at
Start and Stop.
Time setting of SLOW RUN and SLOW STOP is available in range of SLOW RUN about 35 5
seconds, SLOW STOP : about 35 5 seconds / 1700rpm(60Hz), 1400rpm (50Hz) by variable
resistor inside CONTROL PACK.
* It is impossible to stop SLOW STOP shorter time than natural stop of MOTOR.
* In case of need not SLOW operating, turn internal VOLUME to left (counterclockwise) up to
end.
13. Moment Stop Characteristics
13. Moment Stop Characteristics
13. Moment Stop Characteristics
13. Moment Stop Characteristics
There is electric brake function in CONTROL PACK that can make stop moment MOTOR
during operation in a short time of 0.1 seconds.
Braking current works about 0.5 seconds and thereafter will automatically turn off.
There is no retention power catching MOTOR that is possible to adjust desired location only
after stop. In case of need retention power to stop object moving up and down,
select our CONTROL MOTOR mounted electronic brake.
CAUTION
1. In CONTROL PACK, takes about 0.5 seconds to run MOTOR after turning switch for
braking after operating Moment Stop.
2. In CONTROL PACK, if set Speed control variable resistor by 0
or stop moment in state
of put switch to RUN/STOP and then put it to RUN, Motor may run about one rotation that
avoid such operations.
In addition, if repeat RUN/STOP switch in AC power within 0.5 seconds, MOTOR may run
moment rotaion that avoid RUN/STOP in AC Power Terminal..
3. Required stop time is more than 3 seconds in order for stabilized restart after Moment
Stop.