- 23 -
14. Causes and Countermeasures of Failure
14. Causes and Countermeasures of Failure
14. Causes and Countermeasures of Failure
14. Causes and Countermeasures of Failure
Anomalies
Checklist
Breakdown Part
Decision
Countermeasures
MOTOR does not
rotate.
Remove PACK
from SOCKET
and Connect
,
terminal
of SOCKET
If MOTOR rotates, it is
speed setting part or
CONTROLLER part
Check connection with
variable resistor for
speed setting
If MOTOR does not
rotate, it is MOTOR
part
Check MOTOR
connection part
Check CONDENSER
connection for MOTOR
Mount PACK
on SOCKET
and open
,
terminal of
SOCKET
If MOTOR rotates by
maximum speed, it is
speed setting part
Check connection with
Variable resistor for
speed setting
Check connection with
RUN/STOP switch part
If MOTOR does not
rotate, it is MOTOR
part
check connection part
with MOTOR
MOTOR rotates
at maximum
speed.
Remove PACK
from SOCKET
and approve
AC power
If MOTOR does not
rotate, it is speed
setting part or
CONTROLLER part
check connection with
Variable resistor for
speed setting
If MOTOR rotates, it
is MOTOR part
check connection part
with MOTOR
Mount PACK
on SOCKET
and connect
,
terminal
of SOCKET
If MOTOR stops, it
is speed setting
part
check connection with
Variable resistor for
speed setting
check run/stop switch
connection part
check connection of
,
terminal
If MOTOR does not
stop, it is
CONTROLLER part
Anomalies
Checklist
Breakdown Part
Decision
Countermeasures
MOTOR is not
shifted.
CHECK voltage
between
,
If is more than AC
20V, it is speed
check connection with
variable resistor for