![gfm GF-Primo Dolly Instruction Manual And Safety Manuallines Download Page 76](http://html1.mh-extra.com/html/gfm/gf-primo-dolly/gf-primo-dolly_instruction-manual-and-safety-manuallines_2219604076.webp)
75
Error:
The calibration mode disrupts by itself during the procedure:
Solution:
Change from cable to wireless mode or vice versa, then try again.
Error:
Upon switching on the column an incorrect height is shown!
Solution:
Calibrate the column.
If this doesn’t solve the problem and the error is still present, repeat the procedure.
Error:
Display is red:
Solution:
If the display is red it can have a few reasons and in general it is not necessarily an error but also a
signal.
If the display turns red it can mean either
o
the connection to the electronic is disrupted.
o
the motor temperature is too high.
o
the battery voltage is too low.
In these cases
o
in wireless mode switch both units to the next higher channel and check if there is contact
between both units.
o
Check the load on the column and stop operation to enable the motor to cool down.
o
exchange the batteries and recharge the used batteries.
Summary of Contents for GF-Primo Dolly
Page 18: ...17 GF Primo s 3 steering modes and selector position...
Page 20: ...19 GF Secondo s three steering modes and their selector positions...
Page 27: ...26 Handle Rosette Battery cover Exchangeable HCU cover HCU battery Battery cover lock...
Page 34: ...33 Key combination to change the channel Change the channel...
Page 37: ...36...
Page 42: ...41 Tastenkombination zum Kalibrieren des Dolly...
Page 60: ...59 MARKERs 3 to 6 can be selected in the same manner Setting MARKERs...
Page 68: ...67 Recording a sequence...
Page 70: ...69...
Page 88: ...87...